JVC 1.3 Megapixel Vandal Resistant IP Dome Camera
JVC VN-X235VPU
  The VN-X235VPU network dome features a Progressive Scan 1.3 Megapixel CCD with Dual Streaming JPEG and MPEG-4/Motion JPEG, and it also includes a specially designed 2.8~10.5mm Variable-Focal Lens for accurate viewing angles. Read more...

Security Solutions, Inc. - Providing the best in factory sales representation to the security industry for over 20 years!

Call us for a demo 1-800-333-2844

 
Access Power Controller

Altronix Maxim33D

Overview

This unit distributes and switches power to access control systems and accessories. It converts a 115VAC 60Hz input into sixteen (16) independently controlled 12VDC and/or 24VDC PTC protected outputs. These power outputs can be converted to dry form “C” contacts. Outputs are activated by an open collector sink or normally open (NO) dry trigger input from an Access Control System, Card Reader, Keypad, Push Button, PIR, etc. The unit will route power to a variety of access control hardware devices including: Mag Locks, Electric Strikes, Magnetic Door Holders, etc. Outputs will operate in both Fail-Safe and/or Fail-Secure modes. The FACP Interface enables Emergency Egress, Alarm Monitoring, or may be used to trigger other auxiliary devices. The fire alarm disconnect feature is individually selectable for any or all of the sixteen (16) outputs.

Agency Listings

  • UL Listed for Access Control Systems (UL294),  CUL Listed - CSA Standard C22.2 No.205-M1983, Signal Equipment.  File# BP6714.  Effective from February 2008.

 

Altronix Maxim

Download PDFProduct Specs

Build your own Maxim

Features/Specifications

Power Supply/Charger:
  • 12VDC and/or 24VDC output.
  • Output Power Options:
    • a) 5.5 amp @ 12VDC plus 5.5 amp @ 12VDC.
    • b) 5.7 amp @ 24VDC plus 5.7 amp @ 24VDC.
    • c) 5.5 amp @ 12VDC plus 5.7 amp @ 24VDC.
  • 115VAC 60Hz, 7.0 amp input.
  • Input fuse rated @ 3.5 amp.
  • Filtered and electronically regulated outputs.
  • Built-in charger for sealed lead acid or gel type batteries.
  • Maximum charge current .7 amp.
  • Automatic switch over to stand-by battery when AC fails.
  • Zero voltage drop when unit switches over to battery backup (AC failure condition).
  • Short circuit and thermal onerload protection with auto reset.
  • AC input and DC output LED indicators.
  • AC fail supervision (form "C" contact).
  • Battery fail and battery presence supervision (form "C" contact).


Access Power Controller:

  • Sixteen (16) Access Control System trigger inputs.
  • Input options:
    • a) Sixteen (16) normally open (NO) inputs.
    • b) Sixteen (16) open collector inputs.
    • c) Any combination of the above.
  • Sixteen (16) independently controlled PTC protected outputs.
  • Output options:
    • a) Sixteen (16) Fail-Safe and/or Fail-Secure power outputs.
    • b) Sixteen (16) form “C” 5 amp rated relay outputs.
    • c) Any combination of the above.
  • Sixteen (16) auxiliary power outputs (unswitched) (outputs are rated 3.5 amp).
  • Power supply input options:
    • a) One (1) common power input for either ACM8 and lock power (factory installed).
    • b) Two (2) isolated power inputs (external power supply is required).
    • (current is determined by the power supply connected, not to exceed a maximum of 10 amp total).
  • ACM8 board's main fuse is rated @ 10 amp.
  • Red LEDs indicate outputs are triggered (relays energized).
  • Fire Alarm disconnect (latching or non-latching) is individually selectable for any or all of the Sixteen (16) outputs.
  • Fire Alarm disconnect input options:
  • a) Normally open (NO) or normally closed (NC) dry contact input.
  • b) Polarity reversal input from FACP signaling circuit.
  • Alarm output relay indicates that FACP input is triggered (form “C” contact rated @ 1 amp 28VDC not evaluated by UL).
  • Green LED indicates FACP disconnect is triggered.
  • Lifetime Warranty.

 

Enclosure

  • Accommodates up to four (4) 12VDC/12AH batteries.
  • Dimensions: 26”H x 19”W x 6.25”D.
  • 1/2" and 3/4" combination knockouts.

 

Similar Altronix Products

MAXIM33 Power Supply 1: 5.5 amp @ 12VDC or 5.7 amp @ 24VDC, 8 fused protected Fail Safe/Fail Secure outputs. Power Supply 2: 5.5 amp @ 12VDC or 5.7 amp @ 24VDC, 8 fused protected Fail Safe/Fail Secure outputs.

MAXIM3D 5 amp @ 12VDC or 5.4 amp @ 24VDC, 16 PTC protected Fail Safe/Fail Secure outputs.

MAXIM5D 9 amp @ 12VDC, 16 PTC protected Fail Safe/Fail Secure outputs.

MAXIM7D 9.4 amp @ 24VDC, 16 PTC protected Fail Safe/Fail Secure outputs.

MAXIM11D Power Supply 1: 3.5 amp @ 12VDC or 2.7 amp @ 24VDC, 8 PTC protected Fail Safe/Fail Secure outputs. Power Supply 2: 3.5 amp @ 12VDC or 2.7 amp @ 24VDC, 8 PTC protected Fail Safe/Fail Secure outputs.

MAXIM55D Power Supply 1: 9.5 amp @ 12VDC, 8 PTC protected Fail Safe/Fail Secure outputs.
Power Supply 2: 9.5 amp @ 12VDC, 8 PTC protected Fail Safe/Fail Secure outputs.

MAXIM75D Power Supply 1: 9.7 amp @ 24VDC, 8 PTC protected Fail Safe/Fail Secure outputs.
Power Supply 2: 9.5 amp @ 12VDC, 8 PTC protected Fail Safe/Fail Secure outputs.

MAXIM77D Power Supply 1: 9.7 amp @ 24VDC, 8 PTC protected Fail Safe/Fail Secure outputs.
Power Supply 2: 9.7 amp @ 24VDC, 8 PTC protected Fail Safe/Fail Secure outputs.
 

 

Altronix Corporation

(888) 258-7669
(718) 567-8181

(718) 567-9056 Fax

http://www.altronix.com

Document Library

Document LibraryBrowse the Altronix document library for product cutsheets, manuals, and training

Login

Get access to product training, live product demos and our Sales CD






Forgot login?
No account yet? Register

Webinars & Training

September
Everfocus - ECOR264 D1/F1 DVR
September 09, 2010 (4:00 PM)

Russound - C-Series Multiroom
September 15, 2010 (10:00 AM)

Russound - Introducing Collage
September 15, 2010 (2:00 PM)

Everfocus - ECOR264 X-1 DVR
September 16, 2010 (4:00 PM)

Everfocus - NeVio IP Overview
September 23, 2010 (4:00 PM)

View Training Calendar